QCCalcCtrlDifference Action

Purpose

Performs the %Difference QC Calculation.

Input Properties

Property Id

Type

Property Name and Description

Mandatory

qcbatchid string QC Batch ID
Identifier of the QCBatch in which the calculation is done for the QCControl Sample. 1
Yes
qcbatchitemid  string QC Batch Item ID
Identifier of the QCBatch Items (Control QCSamples) for which the %Difference is calculated.
Yes
sdcid sdcelist_sdc SDC
Identifier of the SDC for the SDI that represents the Control QCSample.
Yes
keyid1
keyid2
keyid3
string SDI Key1, SDI Key2, SDI Key3
Key values of the SDI. Up to three Keys uniquely identify each SDI.
Yes
paramlistid sdcelist_paramlist Parameter List
Identifier of the Parameter List associated with the DataSet.
Yes
paramlistversionid string Parameter List Version
Parameter List Version associated with the Parameter List.
Yes
variantid string Parameter List Variant
Parameter List Variant associated with the Parameter List.
Yes
dataset string Data Set Number
Data Set Number (instance of the Parameter List).
Yes
1

You can specify multiple values for these Properties. Use a semicolon to separate each value.

You can pass multiple DataSets of multiple Control Samples by entering multiple values for these Properties. Use a semicolon to separate each value.

Using the following properties as an example:

Property Name Value
QC Batch ID QCB1;QCB2;QCB3
QC Batch Item ID QCBI1;QCBI2;QCBI3
SDC Sample;Sample;Sample
SDI Key1 S01;S02;S03
Parameter List Alkali Metals;Assay;Appearance
Parameter List Version 1;4;3
Parameter List Variant 2;1;3
Data Set Number 3;6;2

Outputs

Property Id

Value

Description

(return) 1 The Action has successfully executed.